4.1

Section 4 Operating Menus

Section 4.1 Main Menu

Figure 4.1 shows the Main Operating Menu. This screen provides an overall view of the functions available
along with pertinent information for each. From this menu the operator may select the Press Control,
Programmable Limit Switch, Automatic Setups (with optional board installed), Tonnage Monitor (with
optional board installed), Die Protection (with optional board installed), Job Setups, Counters, and Motor
Speed Adjust. By depressing the adjacent softkey, the screen will transfer to the Press Control, Automatic
Setups, Tonnage Monitor, Die Protection, Programmable Limit Switch, Counters, or Motor Speed screens.

Stroke

Mode Single Stroke

Drive

Speed

Stroke
Speed

SPM

SPM

0
0

Order

Counter

PC STATUS

Counter OFF

MAIN
SCREEN

PRESS
CONTROL

AUTO
SETS

TONNAGE
MONITOR

DIE
PROTECTION

LIMIT
SWITCH

JOB
SETUPS

0

0

MOTOR
SPEED

STATUS:
READY TO RUN

STATUS:
ALL CONDITIONS OKAY

STATUS:
ALL CONDITIONS OKAY

STATUS:
ALL CONDITIONS OKAY

JOB NUMBER DESCRIPTION
100000 FRONT BRACKET

COUNTER LIMIT QUANTITY STATE

ORDER
BATCH

SPM
0

% LOAD
161

2000

500

7
7

ON
ON

READY TO STROKE

TOP

COUNTERS

6 5 4 3 2 1

7

8

Figure 4.1 Main Menu

The display provides the following information:

1.

The present running status of the press control.

2.

The current status of the automatic slide adjust and air adjust module, if this module is installed.

3.

The present status of the tonnage monitor module, if this module is installed. This includes setpoint
alarms, faults, or a bypass condition.

4.

The present status of the die protection module, if this module is installed. This includes a top stop
or emergency stop due to sensor inputs, faults, or a bypassed condition.

5.

The present Job Number and its description.