LINK Systems OmniLink 5000 User Manual
Page 28

4.10
the RUN position. The display automatically presents one of the menus shown in Figure 4.7 and allows the
operator to choose from one of the stroking modes shown or select the other page of modes. The present
mode is shown at the top of the LCD, and a new mode is selected by pressing the desired softkey. The
display will remain in one of the two menus shown until the mode selector is returned to the RUN or OFF
position. Stroking modes that have been turned off by the factory do not appear on the display and are not
available to the operator.
Stroke
Mode Single Stroke
Drive
Speed
Stroke
Speed
SPM
SPM
0
0
Order
Counter
PC STATUS
Counter OFF
STANDARD
MODES
SETUP
STOP TIME
0
0
Ready to Stroke
TOP
TIMED
INCH
INCH
SINGLE
STROKE
CONTINUOUS
NEXT
GROUP
SETUP AND STOP TIME TEST
TIMED INCH
INCH
SINGLE STROKE
CONTINUOUS
NEXT GROUP OF MODES
Stroke
Mode Single Stroke
Drive
Speed
Stroke
Speed
SPM
SPM
0
0
Order
Counter
PC STATUS
Counter OFF
OPTIONAL
MODES
AUTO
S. S.
0
0
Ready to Stroke
TOP
CONTINUOUS
DEMAND
MAINTAINED
CONTINUOUS
FIRST
GROUP
AUTOMATIC SINGLE STROKE
CONTINUOUS ON DEMAND
OPERATOR MAINTAINED CONTINUOUS
FIRST GROUP OF MODES
Figure 4.7 Stroke Mode Selection
Section 4.3.1 Setup/Stop Time Test
This mode selection requires the use of the Inch buttons to cause stroking. When the buttons are depressed
and held, the slide automatically stops in the downstroke at a programmable position. This permits quick
setup of mechanical feeds driven by the press crankshaft or consistent measurement of downstroke stopping
time for determination of OSHA required safety distance for two hand control and light curtain safety
devices. Release of the Inch buttons or any stop input will cause slide stopping action to be initiated at any
time. Stroke initiation is allowed only with the main motor running in the forward direction.