4.10

the RUN position. The display automatically presents one of the menus shown in Figure 4.7 and allows the
operator to choose from one of the stroking modes shown or select the other page of modes. The present
mode is shown at the top of the LCD, and a new mode is selected by pressing the desired softkey. The
display will remain in one of the two menus shown until the mode selector is returned to the RUN or OFF
position. Stroking modes that have been turned off by the factory do not appear on the display and are not
available to the operator.

Stroke

Mode Single Stroke

Drive

Speed

Stroke
Speed

SPM

SPM

0
0

Order

Counter

PC STATUS

Counter OFF

STANDARD
MODES

SETUP
STOP TIME

0

0

Ready to Stroke

TOP

TIMED
INCH

INCH

SINGLE
STROKE

CONTINUOUS

NEXT
GROUP

SETUP AND STOP TIME TEST

TIMED INCH

INCH

SINGLE STROKE

CONTINUOUS

NEXT GROUP OF MODES

Stroke

Mode Single Stroke

Drive

Speed

Stroke
Speed

SPM

SPM

0
0

Order

Counter

PC STATUS

Counter OFF

OPTIONAL
MODES

AUTO
S. S.

0

0

Ready to Stroke

TOP

CONTINUOUS
DEMAND

MAINTAINED
CONTINUOUS

FIRST
GROUP

AUTOMATIC SINGLE STROKE

CONTINUOUS ON DEMAND

OPERATOR MAINTAINED CONTINUOUS

FIRST GROUP OF MODES

Figure 4.7 Stroke Mode Selection

Section 4.3.1 Setup/Stop Time Test

This mode selection requires the use of the Inch buttons to cause stroking. When the buttons are depressed
and held, the slide automatically stops in the downstroke at a programmable position. This permits quick
setup of mechanical feeds driven by the press crankshaft or consistent measurement of downstroke stopping
time for determination of OSHA required safety distance for two hand control and light curtain safety
devices. Release of the Inch buttons or any stop input will cause slide stopping action to be initiated at any
time. Stroke initiation is allowed only with the main motor running in the forward direction.