LINK Systems OmniLink 5000 User Manual

Page 20

Advertising
background image

4.2

6.

The status of the order and batch counter. This includes the preset limit, the present quantity
produced, and the on/off state of the counter.

7.

A bar graph which represents the current main motor speed.

8.

A bar graph which represents the current main motor load.

Section 4.2 Press Control Menu

Figure 4.2 shows the Press Control Menu. This screen provides detailed information about the press, the
press control, and auxiliary equipment. The softkeys shown active in the PROG mode indicate parameters
that can be changed.

Stroke

Mode Single Stroke

Drive

Speed

Stroke
Speed

SPM

SPM

0
0

Order

Counter

PC STATUS

Counter OFF

PRESS
CONTROL

CHANGE
NUMBER

MOTOR
SPEED

TONNAGE
MONITOR

AUTO
SETS

DIE
PROTECTION

EXIT

0

0

SPM
0

% LOAD
161

READY TO STROKE

TOP

AUXILIARY
COMM.

DIAGNOS

OPERATOR
STATON

Brake Monitor

Limit

Stoptime

Top Stroke Stop

0200

183

mSec

Mid Stroke Stop

0250

0

mSec

Clutch time

0275

0250

mSec

Limit

Actual

Auto Single Stroke Time ……… 5

Sec

Feed Complete Position ……… 25

Degs

Cont. on Demand Time ……….

10

Mins

Auxiliary Equipment Message
Option is not Installed

Reason for the Last Stop
Power Up

Present Running Status
Ready to Stroke

1
2

10

5
6
7

4

8

9

3

Figure 4.2 Press Control Menu

The display provides the following information:

1.

A brake monitor used when the press stops at the top of the stroke.

2.

A brake monitor used when the press stops at any position other than top.

3.

The actual stopping time of the press, measured by the brake monitor.

4.

Clutch engagement time.

5.

Auto Single Stroke Time

6.

Feed Complete Position

Advertising