5.3

Stroke

Mode Single Stroke

Drive

Speed

Stroke
Speed

SPM

SPM

200

0

Order

Counter

PC STATUS

Counter OFF

TOP STOP
CALIBRATE

CHANGE
NUMBER

0

0

Program/Run Switch

TOP

EXIT

MOTOR
SPEED

Speed Advance Top Stop

Stroking
Mode

Single
Continuous

Speed and Stopping Angle

50

340
338

100

330
328

150

320
318

200

310
308

RPM

[ Calculated }

Speed Top Ang

Measured
Stop Ang

Ch A 050 340 340
Ch B 050 340 340

Stop Pos (Setup Mode) = 090

1

2

3

4

5
6

7

8

Figure 5.3 Top Stop Configuration Menu Link
Standard Firmware

The display shows the following information:

1.

The programmed lowest operating speed of the machine.

2.

The programmed speed approximately 1/3 of the way between lowest and highest programmed
speeds.

3.

The programmed speed approximately 2/3 of the way between lowest and highest programmed
speeds.

4.

The programmed highest operating speed of the machine

5.

The programmed angle at which the press will begin to stop when running at each speed shown.
These four angles are used when the press is in a single stroke mode, and will automatically stop at
the end of each stroke.

6.

The programmed angle at which the press will begin to stop when running at each speed shown.
These four angles are used when the press is in continuous running mode.

7.

The actual speed of the crankshaft and computed top stop position recorded by the press control each
time a stroke is made.

8.

The programmed angle at which the press will begin to stop in the downstroke when operated in
Setup/Stop Time Test mode. See Section 5.1.3.