Section 6 Press Control I/O

The System 5000 provides 48 inputs (expandable to 72), 8 programmable limit switch outputs (expandable
to 16), and up to 16 predefined output relays for use on mechanical power presses.

Section 6.1 Press Control Inputs

The standard system 5000 provides 48 inputs arranged as two cards of 24 inputs. Most of these inputs
are dedicated to specific functions that must be permanently strapped if not used. Inputs for the lube
system, hydraulic overload system, and valve monitor allow for different types of systems. These inputs
may be changed and/or disabled through the configuration menus (see sections on lube, hydraulic
overload, and valve monitor). All inputs require a +24 volt source to provide a "HI" signal, and will
default to a 0 volt "LO" signal if the source is removed. The system 5000 provides a +24 volt power
supply for connections to the these inputs. The inputs and their appropriate sections are described below:

Input Card 1

Input # Description

Section

----------------------------------------------------------------------------------------------------
01

Left Normally Open Inch Button

6.1.1

02

Right Normally Open Inch Button

6.1.1

03

Left Normally Open Sta. #1 Run Button

6.1.1

04

Right Normally Open Sta. #1 Run Button

6.1.1

05

Left Normally Open Sta. #2 Run Button

6.1.1

06

Right Normally Open Sta. #2 Run Button

6.1.1

07

Left Normally Open Sta. #3 Run Button

6.1.1

08

Right Normally Open Sta. #3 Run Button

6.1.1

09

Left Normally Open Sta. #4 Run Button

6.1.1

10

Right Normally Open Sta. #4 Run Button

6.1.1

11

All Normally Closed Inch/Run Buttons

6.1.1

12

Top Stop Button

6.1.4

13

Emergency Stop Button Contact 1

6.1.5

14

Emergency Stop Button Contact 2

6.1.5

15

Light Curtain 1

6.1.13

16

Light Curtain 2

6.1.13

17

Operator Station #1 Select

6.1.2

18

Operator Station #2 Select

6.1.2

19

Operator Station #3 Select

6.1.2

20

Operator Station #4 Select

6.1.2

21

Mode Selector Switch in Run Position

6.1.8

22

Mode Selector Switch in Mode Select

6.1.8

23

Automatic Single Stroke/Cont. On Demand Setup Button

6.1.3

24

Continuous Setup Button

6.1.3

Advertising