LINK Systems OmniLink 5000 User Manual

Page 26

Advertising
background image

4.8

Group 5

Programmed in Factory Mode Configuration.
45

Allow Timed Inch

(value)

46

Allow Auto Single Stroke

(value)

47

Allow Continuous on Demand

(value)

48

Allow Maintain Continuous

(value)

49

Maximum Auto Single Stroke time

(value)

50

Max. Continuous on Demand time

(value)

Section 4.2.9.4 Event Log

The controls retains a event log. This log records the reason for the last 128 stops. All reasons for last stop
are recorded, except automatic stop on top. Each entry in the event log contains the time, date, and the type
of stop. The event log is illustrated in Figure 4.4. Stops are displayed in chronological order with the most
recent stop displayed first. The “Next Page” and “Previous Page” softkeys can be used to scroll through the
event log.

Stroke

Mode Single Stroke

Drive

Speed

Stroke
Speed

SPM

SPM

0
0

Order

Counter

PC STATUS

Counter OFF

EVENT
LOG

EXIT

0

0

READY TO STROKE

TOP

NEXT
PAGE

PREVIOUS
PAGE

Date

TimeSubsystem

------------------ ------------------- -------------------------------------
3/21/2000 14:59:41

Event Log Subsystem

Reason:

Top Stop

3/21/2000 14:59:02 Event Log Subsystem
Reason:

Light Curtain # 1

3/21/2000 14:50:49 Event Log Subsystem
Reason:

Die Block

3/21/2000 14:49:22 Event Log Subsystem
Reason:

Auxiliary Top Stop

3/21/2000 14:44:18 Event Log Subsystem
Reason:

Top Stop

3/21/2000 14:42:29 Event Log Subsystem
Reason:

Top Stop

3/21/2000 14:38:48 Event Log Subsystem
Reason:

Top Stop

3/21/2000 14:32:59 Event Log Subsystem
Reason:

Top Stop

Figure 4.4 Event Log

Section 4.2.9.5 Version Information

The version information of the control hardware and software can be viewed by depressing the VERSION
INFO. softkey.

Section 4.2.10 RESET ERROR

The press control screen alerts the operator of an error condition by displaying a RESET ERROR softkey
as shown in Figure 4.5. The reason for the error is shown under Present Running Status. The press can not
be operated until the error is corrected and an operator acknowledges the error by pressing the RESET
ERROR softkey. See the section on Troubleshooting for conditions that require an operator's response.