LINK Systems OmniLink 5000 User Manual

Page 91

Advertising
background image

6.21

Section 6.3.4 Slide Motion

This output (OR-8) turns on when the crankshaft rpm exceeds the minimum strokes/minute threshold.

Section 6.3.5 Mode Outputs

These four outputs provide the present stroking mode of the press control. They function in the following
manner:

Output (OR-9) Inch and Timed Inch Modes
This output turns on when the press control is in Inch or Timed Inch mode.

Output (OR-10) Setup/Stop Time Test, Single Stroke, and Maintain Continuous Modes
This output turns on when the press control is in Setup/Stop Time Test, Single Stroke, or Maintain
Continuous mode.

Output (OR-11) Continuous, Maintain Continuous and Continuous on Demand Mode
This output turns on when the press control is in Continuous, Maintain Continuous or Continuous on
Demand mode.

Output (OR-12) Auto Single Stroke and Continuous on Demand Mode
This output turns on when the press control is in Automatic Single Stroke and Continuous on Demand
mode.

The table below show that status of the stroking mode outputs. The “X” indicates that the output is
energized in the listed mode.

Stroke Mode

OR9

OR10 OR11 OR12

Inch

X

Timed Inch

X

Stop Time Test

X

Single Stroke

X

Continuous

X

Auto Single Stroke

X

Maintain Cont.

X

X

Cont. on Demand

X

X

Section 6.3.6 Stroking Enabled

This output (OR-15) turns on when no stop condition exists and the press control is prepared to engage
the clutch/brake air valve when the proper run buttons are depressed. This output will remain on until a
stop condition occurs or until the press automatically stops on top. It will remain off until all stop
conditions are removed and all operator run buttons are released. Stroking modes that require a prior
action setup button such as Continuous, Automatic Single Stroke, and Maintain Continuous will keep this
output off until the mode has been properly setup. The output will turn on when the prior action setup
button is pressed for at least 1/2 second and will remain on if the proper run buttons are used to initiate

Advertising