Figure 4.10 jobs setup menu – LINK Systems OmniLink 5000 User Manual

Page 35

Advertising
background image

4.17

Section 4.4.4 Restricted PLS Channels

Any programmable limit switch channel that has been restricted in the Press Control Configuration Menu
cannot be altered or bypassed by the operator. Only the first eight channels, PLS 1 to 8, can be restricted.
A restricted channel is indicated as being restricted by an "R" after the channel number in the Description
section of the Limit Switch menu. The softkeys that allow changes to be made to do not exist for restricted
channels. The channel must be configured Un-Restricted before any change can be made to the setpoints or
the description. See Section 5.5 for information on restricting PLS channels.

Section 4.4.5 Counted Outputs

Channels 1, 2, 9 and 10 are programmable limit switch channels with counted outputs. These channels will
not cycle every stroke but only cycle after the number of strokes programmed into the limit value for the
channel. For example, in Figure 4.8, the count limit for channel 1 has been programmed to 3. This channel
will turn on every third stroke. On every third stroke, the channel will turn on at 180 degrees and remain on
for .30 seconds. The channel will remain off at all other times. If it is desired for a counted output channel
to cycle every stroke, the limit should be set to 000 or 001. The maximum value for the limit setting is 255.
The current count is shown in the CNT column. This is a count down counter. When this counter counts
down to 000, the output will cycle in relation to the On and Off settings that have been programmed. The
RESET COUNT softkey will reset the present count values and set them equal to the limit setting. If both
channels on a group of 8 are programmed as counted outputs this will reset both channels, but will not clear
the counters on the other group of 8.

Section 4.5 Job Setups

From the Main Menu, Figure 4.1, pressing JOB SETUPS softkey displays the menu in Figure 4.10 and
allows the user to access the internal file system of the operator terminal. The parameters consisting of
programmable limit switch settings, automatic feed settings, tonnage monitor settings, and die protection
settings for the current job can be saved for later use. In addition, the settings for a job previously stored can
be recalled into the current job.

Stroke

Mode Single Stroke

Drive

Speed

Stroke
Speed

SPM

SPM

0
0

Order

Counter

PC STATUS

Counter OFF

JOBS

NEXT
GROUP

EXIT

0

0

READY TO STROKE

TOP

LAST
GROUP

RECALL
SETUP

STORE
SETUP

ERASE
SETUP

JOB NUMBER

DESCRIPTION

000000001

FIRST EXAMPLE

000000002

SECOND EXAMPLE

000000003

THIRD EXAMPLE

000000004

FOURTH EXAMPLE

000000005

FIFTH EXAMPLE

000000006

SIXTH EXAMPLE

000000007

SEVENTH EXAMPLE

000000008

EIGHTH EXAMPLE

000000009

NINTH EXAMPLE

000000010

TENTH EXAMPLE

000000011

ELEVENTH EXAMPLE

000000012

TWELTH EXAMPLE

000000013

THIRTEENTH EXAMPLE

000000014

FOURTEENTH EXAMPLE

123456789

TWENTY CHARACTERS

Current Job:
Job Number Description
000000001 FIRST EXAMPLE

1

2

Figure 4.10 Jobs Setup Menu

Advertising