LINK Systems OmniLink 5000 User Manual
Page 63

5.16
Section 5.3.1 Auxiliary Lube Systems (option)
If the optional expansion card rack and third input board are provided, two auxiliary lube systems are added
to the lube system menu as shown in Figure 5.7. These auxiliary lubes function independently, and allow for
metered systems only. Each allows the time between lubrication cycles to be set in terms of the number of
press strokes, variable from 10-99,990. A lube cycle duration time can be set for both normal operation and
power up situations. See Section 6.2.1 Aux. Lube System I/O for a detailed description of each type
available.
Section 5.4 Operator Terminal Configuration
The operator terminal configuration menu is shown in Figure 5.8
Stroke
Mode
Drive
Speed
Stroke
Speed
SPM
SPM
200
0
Order
Counter
PC STATUS
Counter OFF
TOP DISP.
CONFIG.
CHANGE
SETTING
0
0
Program/Run Switch
EXIT
ZERO
STROKE
COUNT
ACCESS
CONFIG
AUXILIARY
COMM SETUP
TOP DISPLAY AREA CONFIGURATION
When in a Setup Mode
(Inch, Timed Inch, Etc.)
Area 1:
Drive Speed
Area 2:
Stroking Speed
Area 3:
Distance to Bottom
Area 4:
Current Status
Single
Stroke
When in a Production Mode
(Single Stroke, Cont. . . . Etc.)
Area 1:
Drive Speed
Area 2:
Stroking Speed
Area 3:
Order Count
Area 4:
Current Status
Date: 03/18/2000
Time: 12:38:25 PM
Rod/Stroke Units:
Rod Length:
Stroke Length:
Operator Terminal Type:
Default Language:
In
30.000 in
7.500 in
Link Standard
English
Figure 5.8 Operator Terminal
Configuration
Section 5.4.1 Display Type
The center section and the right side section of the top display area can be configured to show four items.
The choice of items are:
-Drive Speed
-Stroking Speed
-Auto Press Speed (Drive speed with press is not stroking and crankshaft speed when press is
stroking
-Press Control Status
-Press Control Reason for Last Stop
-Total Tonnage (If the control is equipped with a tonnage monitor)
-Counterbalance Pressure (If the control is equipped with automatic counterbalance adjust)
-Shut Height (If the control is equipped with automatic shut height adjust)
-Current Order Count
-Current Down Time Code