LINK Systems OmniLink 5000 User Manual

Page 63

Advertising
background image

5.16

Section 5.3.1 Auxiliary Lube Systems (option)

If the optional expansion card rack and third input board are provided, two auxiliary lube systems are added
to the lube system menu as shown in Figure 5.7. These auxiliary lubes function independently, and allow for
metered systems only. Each allows the time between lubrication cycles to be set in terms of the number of
press strokes, variable from 10-99,990. A lube cycle duration time can be set for both normal operation and
power up situations. See Section 6.2.1 Aux. Lube System I/O for a detailed description of each type
available.

Section 5.4 Operator Terminal Configuration

The operator terminal configuration menu is shown in Figure 5.8

Stroke

Mode

Drive

Speed

Stroke
Speed

SPM

SPM

200

0

Order

Counter

PC STATUS

Counter OFF

TOP DISP.
CONFIG.

CHANGE
SETTING

0

0

Program/Run Switch

EXIT

ZERO
STROKE
COUNT

ACCESS
CONFIG

AUXILIARY
COMM SETUP

TOP DISPLAY AREA CONFIGURATION

When in a Setup Mode
(Inch, Timed Inch, Etc.)

Area 1:

Drive Speed

Area 2:

Stroking Speed

Area 3:

Distance to Bottom

Area 4:

Current Status

Single
Stroke

When in a Production Mode
(Single Stroke, Cont. . . . Etc.)

Area 1:

Drive Speed

Area 2:

Stroking Speed

Area 3:

Order Count

Area 4:

Current Status

Date: 03/18/2000
Time: 12:38:25 PM

Rod/Stroke Units:

Rod Length:

Stroke Length:

Operator Terminal Type:

Default Language:

In
30.000 in
7.500 in

Link Standard
English

Figure 5.8 Operator Terminal
Configuration

Section 5.4.1 Display Type

The center section and the right side section of the top display area can be configured to show four items.
The choice of items are:

-Drive Speed
-Stroking Speed
-Auto Press Speed (Drive speed with press is not stroking and crankshaft speed when press is
stroking
-Press Control Status
-Press Control Reason for Last Stop
-Total Tonnage (If the control is equipped with a tonnage monitor)
-Counterbalance Pressure (If the control is equipped with automatic counterbalance adjust)
-Shut Height (If the control is equipped with automatic shut height adjust)
-Current Order Count
-Current Down Time Code

Advertising