4.26

CHANGE Strokes softkey, enter the new number, and press the ENT key

Section 4.6.4.4 Configure Counter Reset When Order Counter Reset

All counters other than the Order counter can be reset in two ways. The counters can be individually reset
or the counter can be reset when the Order counter is reset.

To change the Reset When Order Counter Reset setting of a counter position the cursor on the value to be
changed, press the CHANGE SETTING softkey.

Section 4.6.4.5 Configure Counter Enable

Each of the seven auxiliary counters can be enabled or disabled. When a counter is enabled, it will appear
on the counter screen. When a counter is disabled it will not appear on the counter screen. The Batch,
Order, and Quality counters are always enabled.

To change the Enable Counter setting of a counter position the cursor on the value to be changed, and press
the CHANGE SETTING softkey.

Section 4.6.4.6 Configure Reset Counters When Job Recalled

This configuration provides the user with the option to restore the counters’ previous count when a job is
recalled. If set to “No”, all counters will be loaded with the previous counts that were registered when the
last job run was terminated. A job is terminated when another job is recalled. For example, Job A was
running on a machine and it was decided that Job B should be run on the machine. The Order Counter for
Job A was at 1020. When Job B was loaded from memory with a Job Recall, the current count for Job A’s
Order Counter, 1020, was stored in memory. The next time that Job A is loaded with a Recall, the count for
the Order Counter will be set to 1020.

If a job is not terminated by a recall of another job, the current counter information will be lost. In the
example above, if Job B was not loaded from memory with a Recall, but instead was set-up by changing some
of the settings that were already loaded for Job A, the current counter information at the end of Job A would
be lost.

A “Yes” configuration will set the current count for all counters to 0 when the job is recalled.

To change the Reset Counter When Job Recalled setting of a counter position the cursor on the value to be
changed, and press the CHANGE SETTING softkey.

Section 4.7 Motor Speed Adjustment (When Provided)

The System 5000 allows the operator to enter stroking speed from the keyboard as shown in Figure 4.16 and
automatically sends this command (as an analog signal) to the motor drive. The stroking speed can be set
over the entire speed range of the press (determined by the configuration), but the press control can
automatically limit the output in certain modes. For example, a press that has a maximum stroking speed of
400 Spm may be configured to limit single stroke mode to less than 250