7.6

Figure 7.8 Operator Terminal and Card Rack Power and Interconnect
Wiring

Section 7.2.2 Clutch/Brake Valve

The connections for the clutch/brake dual valve are provided on the POWER CONNECTOR MODULE
(labeled V1-V5). A typical wiring diagram for an air valve with internal monitor is shown in Figure 7.9.
This interface is 120 VAC (wire labeled 103 is hot and wire labeled 102 is neutral). Additional
connections for monitoring the valve must remain +24 volt DC.

Figure 7.9 Clutch/Brake Valve Connections

Section 7.2.3 Resolver/Encoder

Figure 7.10 shows the field connections between the resolver/encoder assembly and the system 5000 card
rack. A shielded cable with 6 twisted pairs must be used. This cable must be run in a dedicated conduit
from the enclosure housing the card rack assembly to a junction box mounted behind the resolver/encoder
unit. The exposed cable from the junction box to the resolver/encoder assembly should be as short as