LINK Systems OmniLink 5000 User Manual

Page 85

Advertising
background image

6.15

Forward On

Muted from 180 degs to 346 degs

Reverse On

Muted from 0 degs to 180 degs

Both Off

Never Muted

In Single Stroke, Continuous, Trip Mode, and Maintain Continuous modes, the light curtain is muted from
180 degs to 346 degs if the press is stopped. Once the stroke is initiated and motion has been established,
the light curtain is muted from 180 degs to 0 degs to allow auxiliary equipment the entire upstroke in
which to perform its function.

In Automatic Single Stroke mode the light curtain is muted from 180 degs to 346 degs. After stroke
initiation the light curtain is muted from 180 degs to 0 degs while the press is moving. If the press stops
in the region from 346 degs to 0 degs, the press control will wait until motion stops before checking if the
light curtain is still interrupted. If the light curtain is interrupted after this time, further automatic strokes
are prevented and the mode must be manually re-initiated.

Section 6.2 Press Control Inputs (option)

If the optional expansion card rack and third input board are provided, an additional 24 inputs are
available. The inputs and their appropriate sections are described below:

Input Card 3 (4 operator station version)

Input # Description

Section

--------------------------------------------------------------------------------------------
49

Valve Monitor 3

------

50

Valve Monitor 4

------

51

Aux. Lube Fault 1

6.2.1

52

Aux. Lube Fault 2

6.2.1

53

Die Clamp Pressure

6.2.2

54

Run Mode Interlock 2

6.2.2

55

Continuous On Demand Run

6.2.7

56

Input Board 3 Installed

6.2.3

57

Aux. Lube Enable

6.2.1

58

Definable Top Stop

6.2.4

59

Definable Top Stop

6.2.4

60

Definable Top Stop

6.2.4

61

Definable Top Stop

6.2.4

62

Definable Top Stop

6.2.4

63

Definable Top Stop

6.2.4

64

Definable Top Stop

6.2.4

65

Definable Cycle Stop

6.2.5

66

Definable Cycle Stop

6.2.5

67

Definable Cycle Stop

6.2.5

68

Definable Cycle Stop

6.2.5

69

Definable Master Stop

6.2.6

70

Definable Master Stop

6.2.6