System Event Log—Event Configuration

The checkboxes and pull-down menus are not available unless the Syslog Client Mode on the

Syslog Configuration tab and the E-mail Alert on the SMTP Configuration tab are enabled first.

This tab mainly controls whether an event notification is to be sent to the Syslog/SMTP server.

The part of System Event Selection controls the event notification including Device Cold Start,

Authentication Failure, and MAC Violation. With the Syslog/SMTP checkbox ticked, the event

log/email alert will be sent to the system log server/SMTP server respectively. As for the part of

Port Event Selection, port events (link up, link down, and both) can be sent to the system log

server/SMTP server by setting the trigger condition for each port respectively.

•

System event selection: There are three event types—Device Cold Start, Authentication

Failure, and MAC Violation.

-

Device Cold Start: Tick the Syslog/SMTP checkboxes respectively to have the

system issue the event log/email alert to the system log/SMTP server when the

device executes the cold start action.

-

Authentication Failure: When the SNMP authentication fails, the system will issue

the event log/email alert to the system log/SMTP server respectively.

-

MAC Violation: If a device whose MAC address is not in the MAC address table

attempts to access the port, the system will issue the event log/email alert to the

system log/SMTP server respectively. (Note that the Security property of the Port

Control function also has to be set at ‘On’. See the Port Control section for further

details.)

•

Port event selection: Each drop-down menu has four options—Disable, Link UP, Link

Down, and Link UP & Link Down. Disable means no event will be sent to the system

log/SMTP server.

-

Link UP: The system will issue a log message only when the link-up event of the

port occurs.

-

Link Down: The system will issue a log message only when the link-down event of

port occurs.

-

Link UP & Link Down: The system will issue a log message at the time when port

connection is link-up and link-down.