Event Configuration interface

5.2.7 Fault Relay Alarm

The Fault Relay Alarm function provides the Power Failure, Port Link Down/Broken and MAC

Violation detection. Tick the checkbox to enable the relay alarming function. Please refer to the

segment of ‘Wiring the Fault Alarm Contacts’ for the external warning device installation.

Power Failure: With the checkbox ticked the relay device inside the industrial switch

changes its state and the FAULT LED indicator is on if a power failure occurs.

Port Link Down/Broken: With the checkbox ticked the relay device inside the industrial

switch changes its state and the FAULT LED indicator is on if the corresponding port’s

states become link down or broken.

MAC Violation: With the checkbox ticked the relay device inside the industrial switch

changes its state and the FAULT LED indicator is on if a MAC violation event occurs.