Halt – Zilog Z08470 User Manual

Page 191

Advertising
background image

UM008007-0715

Z80 Instruction Description

Z80 CPU

User Manual

179

HALT

Operation

Op Code

HALT

Operands

None.

Description

The HALT instruction suspends CPU operation until a subsequent interrupt or reset is
received. While in the HALT state, the processor executes NOPs to maintain memory
refresh logic.

Condition Bits Affected

None.

M Cycles

T States

4 MHz E.T.

1

4

1.00

0

1

1

1

0

1

1

0

76