Z80 Instruction Set

UM008007-0715

182

Z80 CPU
User Manual

IM 0

Operation

Set Interrupt Mode 0

Op Code

IM

Operand

0

Description

The IM 0 instruction sets Interrupt Mode 0. In this mode, the interrupting device can insert
any instruction on the data bus for execution by the CPU. The first byte of a multi-byte
instruction is read during the interrupt acknowledge cycle. Subsequent bytes are read in by
a normal memory read sequence.

Condition Bits Affected

None.

M Cycles

T States

4 MHz E.T.

2

8 (4, 4)

2.00

1

1

0

0

1

1

1

1

ED

0

1

0

1

0

1

0

0