Z80 Instruction Description

Z80 CPU

User Manual

299

IND

Operation

(HL) ← (C), B ← B – 1, HL ← HL – 1

Op Code

IND

Operands

None.

Description

The contents of Register C are placed on the bottom half (A0 through A7) of the address
bus to select the I/O device at one of 256 possible ports. Register B can be used as a byte
counter, and its contents are placed on the top half (A8 through A15) of the address bus at
this time. Then one byte from the selected port is placed on the data bus and written to the
CPU. The contents of the HL register pair are placed on the address bus and the input byte
is written to the corresponding location of memory. Finally, the byte counter and register
pair HL are decremented.

Condition Bits Affected

S is unknown.

Z is set if B – 1 = 0; otherwise, it is reset.

H is unknown.

P/V is unknown.

N is set.

C is not affected.

M Cycles

T States

4 MHz E.T.

4

16 (4, 5, 3, 4)

4.00

1

1

0

0

1

1

1

1

ED