5.5.5
10/100/1000BaseTx Connectors
Two 10/100/1000BaseTx RJ-45 connectors are located on the rear panel of the standard
version of the CPCI-6115-MCPTM to support Ethernet I/O from the CPCI-6200 SBC. The pin
assignments for these connectors are as follows:
COMn_TD -
COM Port n Transmit Data Output
COMn_RD -
COM Port n Receive Data Input
Miscellaneous:
TMPRSNT_L -
indicates that the MCxx805TM is installed
TMCOM1_L -
used to select COM1 active on processor board or on transition
module
MXCLK -
multiplexed I/O signal clock, 10 MHz
MXSYNC_L -
multiplexed I/O sync signal
MXDI -
multiplexed I/O data-in signal from transition module
MXDO -
multiplexed I/O data-out signal to transition module
I2C_CLK -
I2C Serial Clock for transition module EEPROM
I2C_DATA -
I2C Serial Data for transition module EEPROM
Signal Descriptions
Table 5-9 10BaseT/100BaseTx Connector Pin Assignments
Pin
Signal
1
MDIO0+
2
MDIO0-
3
MDIO1+
4
MDIO2+
5
MDIO2-
6
MDIO1-
7
MDIO3+
8
MDIO3-