9 serial port connector, j16, 10 board insertion/extraction connector, p1, Table 3-10 – Artesyn CPCI-6200 Installation and Use (May 2015) User Manual
Page 71: Front panel latch pinout, p1, Figure 3-3, Serial port connector pinout, j16, Controls, leds, and connectors

Controls, LEDs, and Connectors
CPCI-6200 Installation and Use (6806800J66E)
71
3.3.9
Serial Port Connector, J16
The serial port connector (COM1) is located on the front panel.
Note: G1 and G2 are connected to ground.
3.3.10 Board Insertion/Extraction Connector, P1
A board insertion and extraction connector is located near the front panel. This connector is
used to detect a board insertion or extraction event. The latch connector on the front panel is
connected to this connector.
Pins 1 and 2 indicate board insertion or extraction status. Pin 2 is used with the PCI Bridge while
pin 3 is used with the IPMI controller.
A closed latch indicates board insertion. In this case, pin 2 and 3 are shorted and
FP_EJECTSW = 1, BOARD_EJECT = 0.
Figure 3-3
Serial Port Connector Pinout, J16
6
7
8
9
1
6
5
9
1
2
3
4
5
Not Connected
RXD
TXD
Not Connected
GND
Not Connected
RTS#
CTS#
Not Connected
Table 3-10 Front Panel Latch Pinout, P1
Pin Number
Signal
1
GND
2
BOARD_EJECT
3
FP_EJECTSW
G1
NC
G2
NC