Table 7-19, Request data of get geographical address, Table 7-20 – Artesyn CPCI-6200 Installation and Use (May 2015) User Manual
Page 165: Response data of get geographical address, Control via ipmi

Control via IPMI
CPCI-6200 Installation and Use (6806800J66E)
165
7.3.2.2.1 Request Data
The following table lists the request data applicable to the Get Geographical Address
command.
7.3.2.2.2 Response Data
The following table lists the response data applicable to the Get Geographical Address
command.
If the management controller acts as PM, byte 3 and 4 are equal. If the management controller
acts as BMC, byte 3 is 0x20 and byte 4 is the I2C address it will have if acting as PM. This last
fixed information is needed by system management software to identify the management
controller.
Table 7-19 Request Data of Get Geographical Address
Byte
Data Field
-
-
Table 7-20 Response Data of Get Geographical Address
Byte
Data Field
1
Completion code (IPMI)
2
Geographical address
3
I2C address of the management controller on the IPMB(s) bus(ses) in its
current role
4
I2C address of the management controller on the IPMB(s) bus(ses) in PM role