2 oem commands, Table 7-14, Request data of finish firmware upgrade – Artesyn CPCI-6200 Installation and Use (May 2015) User Manual
Page 163: Table 7-15, Response data of finish firmware upgrade, Table 7-16, Oem commands, Control via ipmi

Control via IPMI
CPCI-6200 Installation and Use (6806800J66E)
163
7.3.1.3.1 Request Data
The following table lists the request data applicable to the Finish Firmware Upgrade command.
7.3.1.3.2 Response Data
The following table lists the response data applicable to the Finish Firmware Upgrade
command.
7.3.2
OEM Commands
The following table shows the OEM commands together with their network function and
command code.
Table 7-14 Request Data of Finish Firmware Upgrade
Byte
Data Field
1..23
None
Table 7-15 Response Data of Finish Firmware Upgrade
Byte
Data Field
1
Completion Code
0: Command executed successfully
0x01..0xFF: Error
Table 7-16 OEM Commands
Command Name
NetFn (Request/Response)
CMD
Description
BMC/PM Change Role
0x30
0x03
See
Get Geographical Address
0x30
0x04
See