Time-to-first-fix, Signal reacquisition, Dynamics – NavCom SF-3050 Rev.B User Manual
Page 128
Advertising

SF-3050 User Guide – Rev B
Time-To-First-Fix
Cold Start:
< 60 seconds
No valid Almanac or
Ephemeris data
available
Warm Start: < 50 seconds
Valid Almanac
available (less than
one year old)
Hot Start:
< 20 seconds
Valid Ephemeris
available (less than
4 hours old)
Typical values measured per ION-STD 101
Signal Reacquisition
< 30 second loss:
< 2 seconds
Dynamics
1
Acceleration:
Up to 6g
Speed:
< 515m/s
1
(1,000 knots)
Altitude: <
18.3km
1
(60,000 ft)
Restricted by USA export laws