Event input configuration, Figure 85: event cable wiring diagram – NavCom SF-3050 Rev.E User Manual

Page 187

Advertising
background image

SF-3050 GNSS Product User Guide

– Rev E

D-161

D ....................... Event Input Configuration

Figure 85 details the wiring of the supplied Event
cable assembly. NavCom part number P/N 94-
310262-3010LF is supplied with earlier SF-3050
production units. P/N 94-310274-3010LF is supplied
with later SF-3050 production units.

Refer to Chapter 3/Event for detailed electrical
specifications.

Table 29 details the wiring configuration required for
Event pulse sensing.

Figure 85: Event Cable Wiring Diagram

Table 29: Event Wiring Connections

Pin #

Signal
Name

Event Sync Wiring

3

Event

Tie Event to Ground

9

Ground

N/A

Once the cable is wired to correspond with the event
pulse requirements, configure the receiver to output
the message containing a time mark

– referenced to

the time kept within the receiver indicating when the
event is sensed (EVENTLATCH, EVENTLATCHA).

The EVENTLATCH and EVENTLATCHA
messages are described in the Sapphire