Parameter tables, 7 vcm bacnet parameters, Bacnet properties for the vcm controller – Orion System PT-Link II BACnet3 User Manual

Page 58: Zone

Advertising
background image

Zone

Zone

7. PARAMETER TABLES

PT-Link II BACnet3 Interface

58

BACnet Properties for the VCM Controller

Parameter

Name

Object

Description

Limits

Supply Air

Temperature

SaTp

AI: 83

Current value of

the supply air

temperature

sensor.

Temperature

Demand

TpDmnd

AI: 84

Based on the

comparison

between the

current Control

Temperature and

the Heating or

Cooling Setpoint

Temperatures.

Does not work

for supply air

control.

VFD Blower

Fan

VfdBwPos

AI: 88

Current position

of the VFD blow-

er fan signal.

VFD Relief

Fan

VfdExPos

AI: 89

Current position

of the VFD relief

fan signal.

Modulating

Gas Valve

Position

MdHt2Pos

AI: 38

Current position

of MODGAS II

modulating gas

valve control.

Reheat Value

Position

Rt2Pos

AI: 60

Current position

of MHGRV

modulating hot

gas reheat valve

control.

Alarm

Group 1

AlrmGrp1

AI: 104

See page 63.

Alarm

Group 2

AlrmGrp2

AI: 105

See page 63.

Alarm

Group 3

AlrmGrp3

AI: 106

See page 63.

Dewpoint

Setpoint

Mirror

DptStM

AI: 110

Mirror of the

DPtSt

“read only.”

Indoor RH

Setpoint

Mirror

InRhStM

AI: 114

Mirror of the
InRhSt “read

only.”

Modulating

Cool

Position

MdClPos

AI: 115

Current position

of the modulating

cooling signal

(Chilled water or

digital compres-

sor).

Modulating

Heat

Position

MdHtPos

AI: 116

Current position

of the modulating

heating signal

(hot water or

SCR heat).

BACnet Properties for the VCM Controller

Parameter

Name

Object

Description

Limits

Application

Software

Version

AppVer

AI: 99

Current version of the

software in the unit.

Alarm

Status

AlmSts

AI: 1

See page

63.

Unit Mode

UnitMode

AI: 123

See page

63.

Control

Status

CtrlSts

AI: 4

Current operational

status.

Control

Temperature

CtrlTp

AI: 9

Current value of the

control temperature

sensor.

Occupied/

Mode

Enable

Cooling

Setpoint

Mirror

ClSt

AI: 7

Occupied/ Mode

Enable Cooling

Setpoint

Mirror.

Duct Static

Pressure

DuctPr

AI: 14

Current value of the

duct static pressure

sensor.

Economizer

Position

EcoPos

AI: 16

Current position of the

economizer damper.

External

Relays 1-2

ExRlys12

AI: 111

See page

63.

External

Relays 3-4

ExRlys34

AI: 112

See page

63.

Indoor

Humidity

InRh

AI: 67

Current value of the

indoor humidity sensor.

Occupied/

Mode

Enable

Heating

Setpoint

Mirror

HtSt

AI: 31

Occupied/ Mode

Enable Heating Setpoint

Mirror.

On Board

Relays

OnRlys

AI: 44

See page

63.

Outdoor Air

Humidity

OaRh

AI: 52

Current value of the

outdoor humidity

sensor.

Outdoor Air

Temperature

OaTp

AI: 54

Current value of the

outdoor temperature

sensor.

Outdoor Air

Wetbulb

OaWtbl

AI: 55

Current calculated value

of the outdoor wetbulb

temperature.

Relief

Pressure

RfPr

AI: 62

Current value of the

building pressure

sensor.

Return Air
CO

2

Level

CO2Level

AI: 150

Current value of the

CO

2

sensor.

Return Air

Temperature

RaTp

AI: 64

Current value of the

return temperature

sensor.

Space

Temperature

SpcTp

AI: 72

Current value of the

space temperature

sensor.

7.7 VCM BACnet Parameters