Verilink ConnecT 56K DSU (896-502110-001) Product Manual User Manual

Page 58

Advertising
background image

Operation

3-28

ConnecT 56K DSU User Manual

Submenu 2 network

A two digit decimal address can be assigned to each ConnecT 56K DSU.
This addressing capability makes it possible to perform remote
configuration and testing in Point to Point and a multi-drop network.

Use the numbers keys to select an address press the Enter key to enter the
address into the system resulting in the system briefly displaying
“Command Accepted” and returning to the active Network Address
menu.

Table 3-13 Network Address Commands

Submenu 3 remote configuration

This option sets up the ConnecT 56K DSU to accept or reject remote
configuration commands. Use the number of the desired mode to activate
the selection press Enter to select the mode resulting in the system briefly
displaying “Command Accepted” and returning to the active Network
Opt. menu with the REMOTE CONFIG. selection active.

Table 3-14 Remote Configuration Commands

Submenu 4 network type

The Network Type option configures the ConnecT 56K DSU for the
specific type of network being used. Use the number of the desired
network type to activate the selection press Enter to select the network
type resulting in the system briefly displaying “Command Accepted” and
returning to NETWORK OPT. menu with the NETWORK TYPE
selection active.

Note:

Additional menus become available when using the Accunet SW
56 or the US Sprint SW56. See Main Menu 4=Dial at the end of
the menu section.

Front Panel

AT Command

Selections Description

XX (Decimal)

_N=xx

Assigns a 2 digit Network Address

Front Panel

AT Command

Selections Description

1=DISABLE

&P4

Disable Remote Configuration

2=DISABLE

&P5

Enable Remote Configuration