Verilink ConnecT 56K DSU (896-502110-001) Product Manual User Manual

Page 67

Advertising
background image

3 = CONFIG

ConnecT 56K DS

User Manual

3-37

Specified times for the SHORT and LONG delays at the different
operating speeds are:

Submenu 7 anti -stream

The ANTI-STREAM option is used to select the anti-stream timeout. The
anti-stream timeout is the maximum time the ConnecT 56K DSU
transmits data into the network from the DTE. This feature prevents one
DTE device on a multi-drop network from continuously tieing up the
transmit circuit back to the master DSU.

The anti-stream timer is reset to zero when RS transitions to the active
state and is updated every second while RS is active. When the anti-
stream timeout expires, the ConnecT 56K DSU stops transmitting DTE
data into the network but continues to accept data from it. This condition
exists until the DTE deactivates the RS input.

Menu map

3=CONFIG/1=Local/2=DTE Opt./7Anti-Stream

Operation

Follow standard operating procedures. When 7=ANTI-STREAM is
flashing: Press the Enter button resulting in the displaying of the first of
the submenu items.

1=Timer Off

2=Time 10 Sec.

Note:

If one of the options chosen involves request to send (RS), then
the delay from RS to CS is selected.

Rate

Short Delay

Long Delay

64

1.1ms

16.1ms

56

1.1ms

16.1ms

19.2

1.5ms

16.5ms

4.8

1.5ms

16.5ms

2.4

1.5ms

16.5ms

Advertising