2 = dte options – Verilink ConnecT 56K DSU (896-502110-001) Product Manual User Manual

Page 59

Advertising
background image

3 = CONFIG

ConnecT 56K DS

User Manual

3-29

Table 3-15 Network Type Commands

Submenu 5 clock source

The Clock Source options specifies the timing source for the ConnecT
56K DSU s internal circuitry. When Operating on a DDS network, the
timing should be FROM NETWORK. On a point to point private
network, one ConnecT 56K DSU must be set for MASTER, the other set
for FROM NETWORK.

Table 3-16 Clock Source Commands

Used to select the configuration parameters that control the operation of
the DTE Interface of the ConnecT 56K DSU.

Front Panel

AT Command

Selections Description

1=DDS

&L0

Any 4-wire DOS network

2=DDS

&L1

ATT&T Switched 56 Service

3=US SPRINT SW56

&L2

Sprint Switched 56 Service

Front Panel

AT Command

Selections Description

1=MASTER

_X0

DSU is the master timing
source

2=FROM NETWORK

_X1

Network RX Signal is timing
source

2 = DTE options