Verilink PRISM 3030 (34-00208.L) Product Manual User Manual

Page 115

Advertising
background image

RFC 1406 - DS1/E1 MIB

105

dsx1SendCode

{ dsx1Config
Entry 7 }

read-write

“This variable indicates
what type of code is
being sent across the
DS1 interface by the
device. The values mean:

dsx1SendNoCode
sending looped or
normal data

dsx1SendLineCode
sending a request for a
line loopback

dsx1SendPayloadCode
sending a request for a
payload loopback

dsx1SendResetCode
sending a loopback
termination request

dsx1SendQRS
sending a Quasi-Random
Signal (QRS) test pattern

dsx1Send511Pattern
sending a 511 bit fixed
test pattern

dsx1Send3in24Pattern
sending a fixed test
pattern of 3 bits set in 24

dsx1SendOtherTest
Pattern
sending a test pattern
other than those
described by this object.”

dsx1SendNoCode(1) - the
unit is not in a BERT Test
and not sending a PLB or
LLB loopup /loopdown
request to the far end.
dsx1SendLineCode(2) - the
unit is transmitting an
in-band LLB loopup
signal. Since this occurs so
quickly, this response
probably will not be seen.
dsx1SendPayload
Code(3) - the unit is
sending an out-of-band
PLB loopup request to the
far end, but since this
occurs so quickly, this
response probably will not
be seen.
dsx1SendResetCode(4) -
the unit is sending either
an in-band LLB loopdown
signal, or an out-of-band
PLB loopdown request, but
since these occur so
quickly, this response
probably will not be seen.
dsx1SendQRS(5) - the unit
is in a Network BERT
transmitting QRSS pattern.
dsx1Send511Pattern(6) -
the unit is in a Network
BERT transmitting 511
pattern.
dsx1Send3in24Pattern(7) -
the unit is in a Network
BERT transmitting 3:24
pattern.
dsx1SendOtherTest
Pattern(8) - the unit is in a
Network BERT and is
transmitting a pattern other
than QRSS, 511, or 3:24.

dsx1SendNoCode(1) -
disable near-end BERT
tests.
dsx1SendLineCode(2) - the
unit will transmit an
in-band LLB loopup
signal.
dsx1SendPayload
Code(3) - the unit will
send an out-of-band PLB
loopup request to the far
end.
dsx1SendResetCode(4) -
the unit will send either an
in-band LLB loopdown
signal, or an out-of-band
PLB loopdown request.
dsx1SendQRS(5) - the unit
will initiate a Network
BERT transmitting QRSS
pattern.
dsx1Send511Pattern(6) -
the unit will initiate a
Network BERT
transmitting 511 pattern.
dsx1Send3in24
Pattern(7) - the unit will
initiate a Network BERT
transmitting 3:24 pattern.
dsx1SendOtherTest
Pattern(8) - the unit will
initiate a BERT and is
transmitting a pattern other
than QRSS, 511, or 3:24.

dsx1Circuit
Identifier

{ dsx1Config
Entry 8 }

read-write

“This variable contains
the transmission vendor's
circuit identifier, for the
purpose of facilitating
troubleshooting.”

Returns the value of the
Circuit Identifier for the
unit, this defaults to
“TxPORT PRISM 3030.”

Sets the value of the
Circuit Identifier for the
unit.

Table C-3

Object Name

Object ID

User Access Object Description

Get

Set

Advertising
This manual is related to the following products: