Alarm parameters, Errored seconds, Severely errored seconds – Verilink PRISM 3030 (34-00208.L) Product Manual User Manual

Page 74: Loss of signal seconds, Unavailable seconds, Dte los/lof seconds, Alarm parameters

Advertising
background image

64

C

HAPTER

4: T

ERMINAL

O

PERATION

Alarm

Parameters

The Alarm Parameters screen (Figure 4-10) allows reviewing and setting alarm
related thresholds for the selected element. These thresholds are the minimum
acceptable performance levels. To modify the parameters, highlight the desired
statistic, type in the new value (any number from 0 to 900) and press Enter. If this
value is later surpassed, an alarm indication appears. A field set to 0 causes the
element not to alarm on that statistic.

If alarm thresholds are edited from the front panel, the corresponding values are not
reflected on this screen until it is exited and then reentered.

Errored Seconds

A one-second period in which at least one logic error occurred.

Severely Errored Seconds

A one-second period in which at least 320 CRC errors or 1 OOF (out -of-frame)
occurred.

Loss of Signal Seconds

A one-second period in which the T1 received signal is interrupted.

Unavailable Seconds

A one-second period in which consecutive severely errored seconds cause an
unavailable state.

DTE LOS/ LOF Seconds

A one-second period in which the T1 received signal (on the optional T1 DTE
interface) is interrupted or the amplitude drops below a certain level.

Figure 4-10 Alarm Configuration Screen

3030 DSU x.xx/x.xx

PRISM 3030

Date: MM/DD/YY

No Far End Response

(Unit Address: 23)

Time: HH:MM:SS

-------------------------------- ALARM CONFIGURATION ---------------------------

Element: [ ]

Errored Seconds (ES): ( 45) Remote Alarm Seconds (RAS): ( 0)

Severely Errored Seconds (SES): ( 5) AIS Seconds (AISS): ( 0)

Loss of Signal Seconds (LOSS): ( 5) Out of Frame Seconds (OOFS): ( 5)

Unavailable Seconds (UAS): ( 0) BPV Seconds (BPVS): ( 0)

DTE LOS/LOF Seconds (LOSS): ( 0) Alarm Reset Timer (seconds): ( 30)

------------------------------------Messages------------------------------------

Local Screen