Configuration reference, Prism 3030 configuration reference – Verilink PRISM 3030 (34-00208.L) Product Manual User Manual

Page 135

Advertising
background image

PRISM 3030 Configuration Reference

Customer Location:

________________________________________

Circuit ID:

________________________________________

Date:

______ / ______ / ______

T1 NET CONFIGURATION

Framing Type:

ESF D4

Line Coding:

AMI B8ZS

Line Build Out:

0 dB

7.5dB

15 dB

22.5 dB

Timing:

INTERNAL NETWORK T1 DTE STATION
SLOT 2A SLOT 2B SLOT 3A SLOT 3B

Station Input Timing:

1.544MHz N

×

56K N

×

64K

(Timing must be set to Station in Timing menu)

Station Timing:

______ Enter a number from 1 to 24 to select the
N multiplier for the Station Input Timing menu.

Zero Suppression:

ENABLE DISABLE

PRM Enable:

ENABLE DISABLE

Alarm Thresholds:

ALARM RESET:___ ES:___ SES:___

(enter # of seconds)

LOSS: ___ OOFS: ___ UAS: ___
RAS: ___ AISS: ___ BPVS: ___

T1 DTE CONFIGURATION

(if equipped)

Framing Type:

ESF D4

Line Coding:

AMI B8ZS

DSX Level (feet):

0–110 111–220 221–330
331–440 441–550 551–660 > 660

Channel Assignment:

IDLE THRU

DTE SLOT 2A

Port Rate Multiplier:

N

×

64K N

×

56K DISABLE

Port Rate:

______ Enter a number from 0 to 24 to select the
N multiplier for the Port Rate Multiplier menu.

Starting Channel #:

______

Enter a number from 1 to 24.

DS0 Channel Assign:

CONTIGUOUS ALTERNATING

Port Transmit Clock:

INTERNAL EXTERNAL OVERSAMPLED

Invert Data:

NO YES

CTS Control:

INTERNAL FORCE TRUE FORCE FALSE

DSR Control:

INTERNAL FORCE TRUE FORCE FALSE

DCD Control:

INTERNAL FORCE TRUE FORCE FALSE

V.54 Loop:

ENABLE DISABLE

RS-232 Port Rate:

NONE SYNCHRONOUS 1200 2400

(if equipped)

4800 9600 14400 19200 28800
38400 48000 56000 64000

DTE SLOT 2B

Port Rate Multiplier:

N

×

64K N

×

56K DISABLE

Port Rate:

______ Enter a number from 0 to 24.

Starting Channel #:

______

Enter a number from 1 to 24.

DS0 Channel Assign:

CONTIGUOUS ALTERNATING

Port Transmit Clock:

INTERNAL EXTERNAL OVERSAMPLED

Invert Data:

NO YES

CTS Control:

INTERNAL FORCE TRUE FORCE FALSE

DSR Control:

INTERNAL FORCE TRUE FORCE FALSE

DCD Control:

INTERNAL FORCE TRUE FORCE FALSE

V.54 Loop:

ENABLE DISABLE

DTE SLOT 3A

Port Rate Multiplier:

N

×

64K N

×

56K DISABLE

Port Rate:

______ Enter a number from 0 to 24.

Starting Channel #:

______

Enter a number from 1 to 24.

DS0 Channel Assign:

CONTIGUOUS ALTERNATING

Port Transmit Clock:

INTERNAL EXTERNAL OVERSAMPLED

Invert Data:

NO YES

CTS Control:

INTERNAL FORCE TRUE FORCE FALSE

DSR Control:

INTERNAL FORCE TRUE FORCE FALSE

DCD Control:

INTERNAL FORCE TRUE FORCE FALSE

V.54 Loop:

ENABLE DISABLE

RS-232 Port Rate:

NONE SYNCHRONOUS 1200 2400

(if equipped)

4800 9600 14400 19200 28800
38400 48000 56000 64000

DTE SLOT 3B

Port Rate Multiplier:

N

×

64K N

×

56K DISABLE

Port Rate:

______ Enter a number from 0 to 24.

Starting Channel #:

______

Enter a number from 1 to 24.

DS0 Channel Assign:

CONTIGUOUS ALTERNATING

Port Transmit Clock:

INTERNAL EXTERNAL OVERSAMPLED

Invert Data:

NO YES

CTS Control:

INTERNAL FORCE TRUE FORCE FALSE

DSR Control:

INTERNAL FORCE TRUE FORCE FALSE

DCD Control:

INTERNAL FORCE TRUE FORCE FALSE

V.54 Loop:

ENABLE DISABLE

VOICE PORT

(if equipped)

Slot 2A:

Channel___, Mode____, Signalling___

Slot 2B:

Channel___, Mode____, Signalling___

Slot 2C:

Channel___, Mode____, Signalling___

Slot 2D:

Channel___, Mode____, Signalling___

Slot 2E:

Channel___, Mode____, Signalling___

Slot 2F:

Channel___, Mode____, Signalling___

Slot 3A:

Channel___, Mode____, Signalling___

Slot 3B:

Channel___, Mode____, Signalling___

Slot 3C:

Channel___, Mode____, Signalling___

Slot 3D:

Channel___, Mode____, Signalling___

Slot 3E:

Channel___, Mode____, Signalling___

Slot 3F:

Channel___, Mode____, Signalling___

Advertising
This manual is related to the following products: