Remote alarm seconds, Ais seconds, Out of frame seconds – Verilink PRISM 3030 (34-00208.L) Product Manual User Manual
Page 75: Bpv seconds, Alarm reset timer
Advertising

Configuration Screens
65
Remote Alarm Seconds
Generated by the terminal equipment when an improper signal is received from the
facility (or after receiving unframed all ones).
AIS Seconds
A one-second period in which all ones are received.
Out of Frame Seconds
A one-second period in which a frame sync loss occurred.
BPV Seconds
A one-second period in which at least one bipolar violation occurred.
Alarm Reset Timer
Determines the number of seconds after alarm conditions clear before indications
are removed.