Groundstart signalling (megacom), Idle state, Call originated from network – Verilink PRISM 3030 (34-00208.L) Product Manual User Manual

Page 99: Cpe answer, Cpe disconnect, Network disconnect, Call originated from cpe, Plar, Private line auto ring, Ground start signalling (megacom)

Advertising
background image

Ground Start Signalling (MEGACOM)

89

Ground Start
Signalling
(MEGACOM)

Idle

State

The FXS application module has the tip open and

48 VDC on the ring towards

the CPE. The CPE has tip and ring open toward the FXS. The FXS transmits both
A and B signalling bits = 0 toward the network, receives an A bit = 0, and ignores
the B bit from the network.

Call Originated

from Network

The FXS application module receives an A bit = 1 and the B bit is ignored from
the network. The change of state of the A bit causes the FXS application module
to do the following.

Set the B Transmit signalling bit to a 1 for approximately 200 ms and then returns
it to a 0.

Send ring voltage with ring cadence toward the CPE.

Send ring back tone towards the network, coincident with the ring cycle.

CPE

Answer

The CPE terminates the loop towards the FXS. The FXS ring trips on loop detect,
depending on the ring cycle. The FXS transmits A and B bit = 0 towards the
network, terminates the ring back tone and opens the audio path.

CPE

Disconnect

The CPE removes termination from the loop. The FXS transmits both A and B
signalling bits = 0 toward the network. The network responds and the FXS receives
an A bit = 0 and ignores the B bit. The FXS opens the tip toward the CPE and
returns to the idle state.

Network

Disconnect

From the network, the FXS receives an A signalling bit = 0 and ignores the B bit.
The FXS opens the tip toward the CPE and transmits both A and B signalling bits
= 0. The CPE responds to the open tip from the FXS by removing Loop
Termination.

Call Originated

from CPE

The CPE grounds the ring lead to the FXS application module. The FXS
application module transmits both A and B bits = 1 toward the network. After 100
ms, the FXS then grounds the tip. The CPE terminates the tip to ring and removes
ring ground. The FXS audio path is active.

PLAR

Private Line

Auto Ring

The PLAR is used in pairs on opposite ends of network. The FXS application
module transmits only two signalling states toward the network:

Loop open from the CPE to the FXS application module, A and B signalling bits
equal 1,

Loop closed from the CPE to the FXS application module, A and B signalling bits
equal 0 and opens the audio path.

Advertising