4-wire e&m, Dnis+ delay seconds, Fxo 4-wire e&m – Verilink PRISM 3030 (34-00208.L) Product Manual User Manual

Page 43

Advertising
background image

Voice Port Configuration

33

MEG/GS: MEGACOM/ Ground

Start

MEGR/LS:

MEGACOM/ Loop Start with Reverse Battery

MEGR/GS:

MEGACOM/ Ground Start with Reverse Battery

PLAR:

Private Line Automatic Ringdown

SLC 96:

SLC 96 Channel Signalling

DID/DNIS:

Direct Inward Dialing / Dialed Number Identification Service
[Dial Pulse Originate (DPO) mode]

DNISW/LS:

Loop Start DNIS (LS-DNIS) with wink

DNISD/LS:

LS-DNIS with delay start

DNISWR/LS:

LS-DNIS with wink and Reverse Battery

DNISDR/LS:

LS-DNIS with delay and Reverse Battery

DNISW/GS:

Ground Start DNIS (GS-DNIS) with wink

DNISD/GS:

GS-DNIS with delay start

DNISWR/GS:

GS-DNIS with wink and Reverse Battery

DNISDR/GS:

GS-DNIS with delay and Reverse Battery

FXO

FXO/LS:

Foreign Exchange Office/Loop Start

FXO/GS:

Foreign Exchange Office/Ground Start

FXO UVG:

Foreign Exchange Office/Universal Voice Grade

FXO UVGR:

Foreign Exchange Office/Universal Voice Grade
with Reverse Battery

DID/DNIS:

Direct Inward Dialing/Dialed Number Identification Service
[Dial Pulse Terminate (DPT) mode]

4 -Wire E&M

F-3010-200--112

F-3010-200--114

Type I: Signalling

Yes

Yes

Type II:

Signalling

Yes

Yes

Type III:

Signalling

Yes

Yes

Type IV:

Signalling

No

Yes

Type V:

Signalling

No

Yes

TO:

Transmission Only

Yes

Yes

DNIS+ Delay

Seconds

If signalling mode has a delay, it can be set from 1 to 5 seconds.

Advertising