System Utilities

41

YELLOW/REMOTE

Indicates that a remote (yellow) alarm indication is being received.

T1 DTE

Alarms

T1 DTE alarm status is reported using the same parameters as defined for Network
Alarms in the preceding paragraphs. The front panel alarm indicator and the rear
panel alarm relay contacts are a function of the network alarm thresholds, not the
T1 DTE interface.

System Utilities

The System Utilities display (Figure 3-22) allows performing the various functions
shown in Figure 3-21 and described in the following paragraphs.

Defaults are shown underlined.

Edit

Password

The unit is factory shipped with the password disabled (factory default). A
password is selected by entering up to 10 alphanumeric characters. Each character
is entered using the up or down arrow keys until the desired character is displayed.
The right arrow moves the cursor to the next position. Continue this pattern until
the last character is selected and then press Select. The password function is
disabled by selecting this field and pressing Select without selecting any
characters.

The password is case sensitive. During log on, it must be entered exactly as it was
programmed.

Display

View Angle

Date

Time

Edit

Password

User Info

Unit ID

Call On

Alarm

Adjusts front

panel screen

contrast.

The default value

is 8.

Enter

date in

MM:DD:YY

format.

Enter

time in

24-hour

HH:MM:SS

format.

Enter line of

text, such as

site location,

circuit ID for

idle top line

Off

Direct

Dial

Dial NMS

Remote

Link

FDL

Ch. 1 - 24

None

NMS

Address

Enter 3 digits

in range of

1 - 250.

The default

value is 251.

NMS

Bit Rate

1200
2400
4800
9600

19200

SUPV

Bit Rate

1200
2400
4800
9600

19200

Boot

Mode

Local

NMS

Alarms

Cut Off

Disable

Enable

Alarm

Notifi-

Edit

Primary

Edit

Second.

Edit

Element

Enter up to 10

characters using

and keys.

Accept and

move with right

arrow.

cation

String

String

ID

Figure 3-21 System Utilities Menu Diagram

System Utilities

> Edit Password

Figure 3-22 System Utilities Screen

Advertising