Maintenance reset, Coa parameters, Alarm notification – Verilink PRISM 3030 (34-00208.L) Product Manual User Manual

Page 85: Primary phone#, secondary phone, Elementid, Coa parameters, Primary phone #, secondary phone # element id

Advertising
background image

Utilities Screen

75

The reset operation sets all parameters to the factory default settings and zeros all
performance registers. If the reset operation is not a satisfactory option, then call
Verilink Customer Support for a one-time-use back door password (see Ordering
Numbers on page 121)
.

Maintenance Reset

Clear all user-selectable parameters, performance registers, passwords, and alarms.
All alarm threshold parameters is reset to default values. The unit reloads start-up
configuration settings from the default parameters stored in ROM. Pressing Enter
on this field brings up a warning prompt asking whether or not to perform the reset
function.

COA

Parameters

The following fields pertain only to call on alarm functions.

Alarm Notification

Controls the remote alarm reporting. The choices are as follows.

OFF.

Disables alarm reporting.

DIRECT.

Sends reports to a printer or terminal connected directly to the

supervisory port.

DIAL.

Sends reports through an attached AT command set compatible modem

connected to the SUPV serial port, which must dial out to a remote modem. The
message format is described in the Element ID field.

DIAL NMS.

Sends reports through a modem to an 8100A.

Primary Phone#, Secondary Phone#

ASCII strings for the primary and secondary call on alarm phone numbers used in
the DIAL and DIAL NMS modes. The strings must not include the ATDT
command prefix.

The unit makes three attempts to connect using the primary number. If all three
attempts fail, the unit makes three attempts to connect using the secondary number
(if it is not blank). If the secondary number fails, the unit waits five minutes and
then attempts to communicate using the primary number again. When a connection
is detected, the unit outputs the notification message and disconnects.

Element ID

Allows the entry of an ASCII string (29 characters in length) which identifies the
unit to the device receiving the alarm notification messages.

Call on alarm messages are reported in the following format in the DIAL or
DIRECT modes only.

Element ID HH:MM:SS MM/DD/YY CR LF

NET Alarms: alarms CR LF

DTE Alarms: alarms CR LF

Advertising
This manual is related to the following products: