Specifications, Network interface, Equipment interface – Verilink PRISM 3030 (34-00208.L) Product Manual User Manual

Page 13: T1 dte port (optional), Dte slots 2a through 3b, Voiceapplication modules (optional), Network interface equipment interface, T1 dte port (optional) dte slots 2 a through 3b, Voice application modules (optional)

Advertising
background image

Specifications

3

Specifications

Network

Interface

Line Rate:

1.544 Mbps (

±

50 ppm)

Line Framing:

D4 or ESF

Line Code:

AMI or B8ZS

Input Signal:

0 to

27 dB ALBO

Connection:

RJ-48C jack, 100

(

±

5%)

Output Signal:

3.0 V (

±

10%) base-peak into 100

with protection

Line Build Out:

0,

7.5,

15,

22.5 dB attenuation

Transient Voltage:

1000 V protection, fused input and output

Jitter Control:

per TR 62411 and T1.403

Timing Source:

Internal, recovered line clock, external DTE, station clock

Ones Density:

B8ZS,

Ν×56

bit stuffing, alternate fill; complies with TR 62411

Equipment

Interface

T1 DTE Port (optional)

Line Rate:

1.544 Mbps (

±

50 ppm)

Line Framing:

D4 or ESF

Line Code:

AMI or B8ZS

Input Signal:

DSX1 to

6 dB

Connection:

RJ-48C jack, 100

(

±

5%)

Output Signal:

Selectable DSX1 level from 0 to 655 feet in six incremental levels

DTE Slots 2 A through 3B

Compatibility:

EIA-530 (RS-422), female DB-25; ITU V.35, female 34 -pin;
EIA-232, female DB-25

Data Rate:

Synchronous,

Ν×56

kbps or N

×

64 kbps (where N = 1 to 24);

independent selection on each port

Clocking:

Internal, External, or Oversample

Data Invert:

Independent selection on each port

Voice application

modules (optional)

FXS

Applications:

FXS (Foreign Exchange Station), In WATS,
Out WATS, Auto Ringdown, Universal Voice Grade (UVG;
Requires Verilink equipment at each end.), Direct Inward
Dialing (DID), Dialed Number Identification Service (DNIS),
Loop Start DNIS (LS-DNIS), Ground Start DNIS (GS-DNIS),
Automatic Number Identification (ANI), and Custom Local
Area Signalling Service (CLASS)

Connector:

AMP 50-pin (25 pairs), female

Signalling:

Loop, Ground, MEGACOM

®

, SLC

®

96

Advertising