V T 1 0 0 I n t e r f a c e

4-21

Idle Pattern

Selects the DS0 idle pattern sent by the unit and lets the unit determine if the
DS0 idle pattern has been sent by the other end.

Values: 0x00

0xFF

Default: 0x7F

Figure 4.17

DS0 Monitor 24 Hour History Screen

Figure 4.18

DS0 Monitor 30 Day History Screen

The DS0 Monitor 24 Hour History and 30 Day History screens show the
following statistics for the specified period.

Period

Period for which the DS0 monitor history is displayed.

Timestamp

System-up-time value during which the utilization historical period was
completed.

% Utilization of __

DS0(s)

Percent of DS0s utilized (

1, 0

100%) over the period. A

1 indicates an

invalid value or unavailable data.

High Utilization

Seconds

Number of seconds (0

900) greater than or equal to the high utilization

parameter specified for the period in the utilization alarm table.