V T 1 0 0 I n t e r f a c e

4-79

Figure 4.75

HDLC Monitor Details Screen

Service Attached

Service to which an HDLC detector is assigned and for which statistics are
collected.

Values: Service Index, Disabled
Default: Disabled

NOTICE:

A Serial 1 service can only be attached to Detector 1, and a Serial 2
service can only be attached to Detector 2.

Service (bps)

Bit rate of the service for which statistics are being collected.

Alarm Reset Timer

(sec)

Number of seconds a utilization alarm condition must not be present before
the unit resets the alarm. Zero (0) indicates the timer is disabled.

Values: 0

900

Default: 30

Rx High Utilization

(%)

What the user considers Rx high utilization (expressed as a percentage) for
this service.

Values: 1

100

Default: 75

Rx High Threshold

(sec)

Number of seconds Rx high utilization must be present before an alarm
reports.

Values: 0

900

Default: 0 (Rx High Utilization Alarm Disabled)

Rx End of Day Low

Utilization %

What the user considers Rx low utilization at the end of the day for this
service.

Values: 0

100

Default: 0 (Rx Low Utilization Alarm Disabled)