W e b S e r v e r I n t e r f a c e

3-43

Bits Over Be Alarm

Reports if the Tx over Be threshold has been exceeded.

Congestion Threshold

Sets the Rx Congestion alarm threshold. This threshold is the number of
frames received with BECN/FECN. Setting this field to “0” (zero) disables
the alarm.

Congestion Alarm

Reports if the Rx Congestion threshold has been exceeded.

BECN in CIR

Reports if Backward Explicit Congestion Notification (BECN) has been
received within CIR.

UAS Threshold

Sets the UAS (Unavailable Seconds) alarm threshold. This threshold is the
number of seconds passed that the DLCI is unavailable. Setting this field to
“0” (zero) disables the alarm.

UAS Alarm

Reports if the UAS threshold has been exceeded.

The DLCI Details screen provides the following user-activated buttons:

DLCI Statistics Screen

Clicking the “DLCI Statistics” button on the DLCI Details screen will display
the screen shown in Figure 3.33.

Figure 3.33

DLCI Statistics Screen

Button

Function

Submit

Sets and activates any DLCI parameters values that have been
changed.

Clear Alarms

Clears all DLCI alarms.

DLCI Statistics

Displays a table of the statistics for this DLCI.

DLCI Table

Displays a table of all DLCIs on a specific frame relay service, with
their state and alarm conditions.