CHAPTER 9 • DRIVER REFERENCE

115

munication only).

˽

Timeout – Time in milliseconds Collector will attempt to make a modem connection

before returning.

˽

Retry Count – If Collector cannot make a modem connection in the timeout period

(or if it runs into a NO CARRIER error), it will try again this number of times before

abandoning the collection attempt completely.

˽

Read Delay (ms) – Milliseconds Collector will wait after sending a command before it

attempts to read the response.

˽

Device Password – Some Diamond devices are password protected and need a pass-

word sent for each command before it will respond.

˽

Daytime Collection – If not checked, the Diamond driver will ignore data collection

command during daytime hours (7 a.m. to midnight).