CHAPTER 5 • SENSOR CONFIGURATION PAGE

53

Figure 5.4 – Data Status Detail

It is possible for communication to be 100% and for data to still be missing, but using the

data status information will be useful in troubleshooting. Internally, Collector fills in data

gaps by tracking which times have been successfully collected and which are still missing.

This tracking occurs as soon as the sensor is added to Collector.

The graph can be interpreted using the following information:

˽

Navy indicates the data is present.

˽

Gray indicates the data is missing.

˽

White indicates that the oldest time being tracked is less than 100 interval periods in

length.

Note

Use the the Data Validation Report to see what data is actually in the database.

Sensor Information

The sensor information section of the Sensor Info bar contains the sensor type, description

and location. This information is read directly from the sensor and is therefore uneditable.

However, depending on the sensor type, you may need to enter this information in the

Sensor Config page. You can choose what sensor information to display by using the Select

Sensor to Display menu (see the Select Sensor to Display Menu section below).

View Log Button

The View Log button takes you to the Sensor Error Log page, which will display the recent

communication/collection errors for the sensor.