7.2 Common configuration options

7.2.1 Serial port settings

Regardless of the selected port function, each port needs 
to be configured to match the parameters of the equipment 
attached to the port. As the configuration of a port function is 
edited, the options displayed in Figure 117 will be shown.

Figure 117: Common port configuration parameters

For each port, the following parameters can be set:

Baudrate
The port can be configured for any standard baudrate from 
300 baud to 230400 baud.

Databits
The port can be configured for operation with 5 to 8 databits. 

Stopbits
The port can be configured for operation with 1 or 2 stopbits.

Parity
The port can be configured for none, odd or even parity.

Flow control
The serial server port can be configured for the following 
modes: