3.3.5 Connect on Demand

The connect on demand settings are only valid if the Wireless 
connection state has been set to always connect, refer to sec-
tion 3.2.4.

The options are:

Idle time to disconnect:
Specify the time in minutes after the last data receive or 
transmit to terminate the connection.

Minimum time between reconnections:
Specify the minimum time in seconds to re-connect to the 
network after a disconnect from the network.

3.4 Circuit Switched Data (CSD) Mode

MRD-3xx can be configured to work in Circuit switched 
Data (CSD) mode. This mode works in a similar manner to a 
traditional dial-up unit. The MRD-3xx can be "dialed" by call-
ing its associated data number, the MRD-3xx will answer the 
call and make a direct connection from the wireless port to a 
serial port. Once connected all data coming into the wireless 
port will be directed to the serial port and all data received 
by the serial port will be directed to the wireless port. When 
in CSD mode the MRD-3xx can only connect one serial port 

to the wireless port. The LAN interface will still be active and 
the MRD-3xx will still be accessible however no packet will 
be able to be routed to the wireless port. The MRD-3xx can 
operate in CSD "Single port" meaning only one serial port can 
be accessed, or CSD "Multiplexed" meaning one of the serial 
ports can be selected on connection.

Note: This section does not describe the serial port configu-
ration, for details on configuring the serial ports refer to sec-
tion 7 Serial Server.