Westermo MRD-3x0 User Manual

Page 164

Advertising
background image

164

6623-3201

As shown in Figure 120, the following options can be set for 
the Raw TCP Client/Server:

Network type
The Raw TCP serial server can be configured for three differ-
ent network modes:

Accept
The serial server will listen for TCP connections on 
the specified port number.

Connect
The serial server will establish a TCP connection to 
the specified address and port number.

Accept and Connect
The serial server will normally listen for TCP connec-
tions on the specified port number, however, if data is 
received at the serial port and no connection exists,  it 
will attempt to establish a connection to the specified 
address and port number.

Connect address
For Connect or Accept and Connect network modes, this is the 
address the server will attempt to connect to. The address 
entered should be in IPv4 decimal dotted notation.

Connect port
For Connect or Accept and Connect network modes, this is the 
TCP port number the server will attempt to connect to. The 
value entered should be a valid TCP port number.

Timeout after failed connect
For Connect or Accept and Connect network modes, if a con-
nection request has failed, the server will wait the amount 
of time (in seconds) specified in this field before attempting 
another connection request. While a short timeout may cause 
the connection to be established more quickly, it may also 
cause greater network traffic if the remote host is unavailable 
and repeated attempts fail.