Timeout before sending
The timeout allows data accumulated by the framer to be sent 
after a specified period of serial receive inactivity. This pre-
vents data from being held in the framer indefinitely should no 
more data arrive on the serial port. The timeout is set in 100 
millisecond units, so, for example, a one second timeout would 
be set as a value of 10.

Immediate send character matching
This field allows the framer to be configured so that if certain 
characters are received the accumulated data is immediately 
sent. The character matching can function in two modes:

Match any character
If either of the characters set the in Match characters field are 
received, the data will be sent immediately.

Match all characters
If both of the characters set in the Match characters field are 
received in order, the data will be sent immediately.

Match characters
Used in conjunction with the Immediate send character 
matching field, these characters determine what data will 
cause an immediate send. The values are entered as a hex 
value, so, for example, a newline (ASCII 10) would be entered 
as 0A. To delete a value, clear the text in the field.

Characters to wait after match
Used in conjunction with the Immediate send character 
matching field, this count determines how many additional 
characters will be received after an immediate match charac-
ter is detected. This is useful if some trailing characters always 
follow the match character.