As shown in Figure 124, the following options can be set for 
the Unit Emulator:

Dial out destination address
This field determines how the emulator will handle dial 
requests from the serial port (ATDxxxx commands). The dial 
address may be set by:

Fixed destination
Regardless of the value entered after the ATD command, the 
emulator will always connect to the host specified in the Fixed 
destination address and Fixed destination port fields.

From dial string
The emulator will parse the ATD command to extract the 
destination address and port number. The examples below 
show the two different formats that can be used to create a 
connection to the address 192.168.2.200 and port number 
6001.

Dotted Dial string is ATD 192.168.2.220:6001

Padded Dial string is ATD 0109020106080202020006001

From phone book
When a dial command is entered, the emulator will look up 
the unit's phone book and attempt to translate the number to 
an address and port number. More details on the phone book 
can be found in section 7.9.

Accept incoming calls
When set, the emulator will listen for TCP connections on the 
port number specified in the Accept port field. When a con-
nection is received, the emulator will indicate a ring condition 
at the serial port. The equipment can then answer the call or 
wait for the emulator to automatically answer. Once answered, 
the emulator will indicate that the connection is open and 
data will pass between the remote host and the serial port.