Westermo MRD-3x0 User Manual

Page 172

Advertising
background image

172

6623-3201

Accept port
This is the TCP port number that the server will listen for 
connections on.

On-answer signaling
When set, the emulator will behave as follows: When accept-
ing an incoming connection, the emulator will transmit a single 
byte to the remote host when the call is answered. When 
establishing an outgoing connection, the emulator will wait 
for the first byte of data before signaling that the call has con-
nected at the serial port.

TCP keepalive time
When set to a value greater than 0, TCP keepalives will be 
enabled for connections, with probes sent at the frequency 
specified (minutes). This may assist in detecting failed connec-
tions.

Rings until answered
This field determines the default number of rings the emulator 
will wait before automatically answering a call. This is equiva-
lent to setting the ATS0 S-Register in a conventional unit.

DCD mode
This field determines the default state of the Data Carrier 
Detect (DCD) handshaking line. The following modes are sup-
ported:

Always on
Regardless of the online state of the emulator, the DCD line 
will be active (equivalent to AT&C0).

Follow carrier
The DCD line will be active when the emulator is in the 
online state (equivalent to AT&C1).

Advertising