[SwitchA] mpls te

[SwitchA-te] quit

[SwitchA] rsvp

[SwitchA-rsvp] quit

[SwitchA] interface vlan-interface 1

[SwitchA-Vlan-interface1] mpls enable

[SwitchA-Vlan-interface1] mpls te enable

[SwitchA-Vlan-interface1] rsvp enable

[SwitchA-Vlan-interface1] quit

# Configure Switch B.

<SwitchB> system-view

[SwitchB] mpls lsr-id 2.2.2.2

[SwitchB] mpls te

[SwitchB-te] quit

[SwitchB] rsvp

[SwitchB-rsvp] quit

[SwitchB] interface vlan-interface 1

[SwitchB-Vlan-interface1] mpls enable

[SwitchB-Vlan-interface1] mpls te enable

[SwitchB-Vlan-interface1] rsvp enable

[SwitchB-Vlan-interface1] quit

[SwitchB] interface vlan-interface 2

[SwitchB-Vlan-interface2] mpls enable

[SwitchB-Vlan-interface2] mpls te enable

[SwitchB-Vlan-interface2] rsvp enable

[SwitchB-Vlan-interface2] rsvp bfd enable

[SwitchB-Vlan-interface2] quit

[SwitchB] interface vlan-interface 4

[SwitchB-Vlan-interface4] mpls enable

[SwitchB-Vlan-interface4] mpls te enable

[SwitchB-Vlan-interface4] rsvp enable

[SwitchB-Vlan-interface4] quit

[SwitchB] interface vlan-interface 6

[SwitchB-Vlan-interface6] mpls enable

[SwitchB-Vlan-interface6] mpls te enable

[SwitchB-Vlan-interface6] rsvp enable

[SwitchB-Vlan-interface6] quit

# Configure Switch C in the same way that Switch B is configured. Configure Switch D, Switch E,
and Switch F in the same way that Switch A is configured. (Details not shown.)

4.

Configure an MPLS TE tunnel on Switch A, the ingress node of the primary CRLSP:
# Configure an explicit path named pri-path for the primary CRLSP.

[SwitchA] explicit-path pri-path

[SwitchA-explicit-path-pri-path] nexthop 2.1.1.2

[SwitchA-explicit-path-pri-path] nexthop 3.1.1.2

[SwitchA-explicit-path-pri-path] nexthop 4.1.1.2

[SwitchA-explicit-path-pri-path] nexthop 4.4.4.4

[SwitchA-explicit-path-pri-path] quit