Display screen – HEIDENHAIN ND 1300 OED and Crosshair Systems User Manual
Page 213

195
10
Setup
Display screen
The Display screen contains fields for configuring dis-
play resolution and other LCD display parameters.
Display resolution
The display resolution fields are used to specify the res-
olution of measurements shown on the DRO and other
screens. Displayed numbers will be round ed as the dis-
play resolution is decreased below that of the input. The
table below il lustrates how the display is governed by
the display resolution setting.
Encoder input Display resolution Displayed value
1.567 0.0001 1.5670
1.567 0.001 1.567
1.567 0.01 1.57
1.567 0.1 1.6
1.567 1 2
NOTE
Display resolution should never be higher than the encoder resolution. Specifying
display resolutions that are higher than encoder resolutions can lead to misleading
displays of values.
To specify display resolution,
touch the data field of the desired
Display category and enter the
desired resolution using the num-
ber keys.
Display Screen