Electrical Installation 2 - 17

Shunt Connector CN15

The shunt connector CN15 is described in this section. Shunt connector along with parameters H4-07 and H4-08 select the
signal range of the analog output terminals FM and AM.

Shunt connector CN15 is only available when the optional Terminal Card with the 4-20mA Analog Output Monitor is installed
(Model No. ETC618120). See Chapter 7 for installation of the optional Terminal Card.

The function of various shunt connector CN15 configurations is shown in Table 2.8.

Fig 2.12 Shunt Connector CN15 Location

The software configuration for the analog output monitor signal type is listed below:

Table 2.8 Shunt Connector CN15 Configuration Options

CN15

Analog Output Monitor Configurations

Voltage Output (0-10 VDC) for terminals FM-AC (CH1) and AM-AC (CH2)

Current Output (4-20mA) for terminals FM-AC (CH1) and AM-AC (CH2)

Voltage Output (0-10 VDC) for terminals FM-AC (CH1)
Current Output (4-20mA) for terminals AM-AC (CH2)

Current Output (4-20mA) for terminals FM-AC (CH1)
Voltage Output (0-10 VDC) for terminals AM-AC (CH2)

Parameter

No.

Parameter Name

Digital Operator Display

Description

Setting

Range

Factory

Setting

Menu

Location

H4-07

Terminal FM Signal Level
Selection
AO Level Select1

0: 0 - 10 V
2: 4-20 mA

0 or 2

0

Programming

H4-08

Terminal AM Signal Level
Selection
AO Level Select2

0: 0 - 10 V
2: 4-20 mA

0 or 2

0

Programming